Goldray Glass QuickFrost™ is a switchable privacy glass that allows a glass lite to go from opaque privacy, to non-privacy glass at the flick of a switch. This product has quickly gained popularity in commercial environments, including corporate and healthcare settings due to its ability to allow light transmission, while quickly providing privacy when needed. In addition to a sleek aesthetic, QuickFrost™ offers a non-porous, easy-to-clean, surface that is ideal for maintaining a clean environment. When you are ready to install, QuickFrost™ is versatile and can fit within a variety of framing solutions. Based on your design specifications, our team will assist you in determining the best panel size and installation method to ensure you can quickly and easily incorporate QuickFrost™ into your next project.

QuickFrost™ is made by laminating a switchable film between two glass lites and attaching the glass to a power source. When an electric current is applied to the film, the LCD particles react, causing the crystals within the film to align and the glass to appear in it’s non-privacy state. In it’s “off” state, with no electricity applied, the crystals will revert back to their original position in the film, offering enhanced privacy as the view through the glass is obstructed. In recent years, new films have been produced that require less electricity to activate the LCDs, improving the overall clarity of the glass in it’s non-privacy state. Goldray Glass currently uses the latest generation of switchable film, ensuring a high-quality product that is more accessible to architects and designers than ever before.

Applications

partitions

signage

marker boards

Product Specifications


Availability

Glass Thickness:
The total thickness of a completed panel is approx. 9.5mm (using two laminated 4mm glass panels).
Glass Edge Condition:
There will be up to a ⅛“ (3mm) clear area around the perimeter of the glass. This will be covered when installed within most framing solutions.
Supply Voltage:
Goldray Glass recommends using 36 VAC to 60 VAC (any voltage ≥ 65 VAC & DC current will damage the film). We also recommend turning the glass panel off for at least one hour every 24 hours.
Installation Method:
Glass panels must be hard-wired using the 22 AWG wire leads installed on the glass. All panels must be wired by a certified electrician.
Bus Bar Location:
There are four bus bar location options for QuickFrost™, please specify the desired bus bar location when ordering. Contact Goldray Glass for more information.

Technical Data

UV Light Transmission:
<1%
Haze:
In the “ON” State: <5% (Based on a viewing angle of 90 degrees from the glass surface)
Color Tolerance:
1 Delta E (CIE LAB) (ASTM D 2244)
ANSI 97.1:
Passed
16 CFR 1201:
Passed

Applicable Industry Standards

ASTM C1036
Standard Specification for Flat Glass
ASTM C1048
Standard Specification for Heat-Treated Flat Glass - Kind HS, Kind FT Coated and Uncoated Glass
ASTM C1172
Standard Specification for Laminated Architectural Flat Glass